[1]李茂林,浦承皓,王卫东,等.奥氏体不锈钢无缝钢管晶间腐蚀试验要求探讨[J].中国材料进展,2017,(11):062-66.[doi:10.7502/j.issn.1674-3962.2017.11.08]
 LI Maolin,PU Chenghao,WANG Weidong,et al.Discussion on Intergranular Corrosion Test Requirements of Austenitic Seamless Stainless Steel Pipe[J].MATERIALS CHINA,2017,(11):062-66.[doi:10.7502/j.issn.1674-3962.2017.11.08]
点击复制

奥氏体不锈钢无缝钢管晶间腐蚀试验要求探讨()
分享到:

中国材料进展[ISSN:1674-3962/CN:61-1473/TG]

卷:
期数:
2017年第11期
页码:
062-66
栏目:
前沿综述
出版日期:
2017-11-30

文章信息/Info

Title:
Discussion on Intergranular Corrosion Test Requirements of Austenitic Seamless Stainless Steel Pipe
作者:
李茂林1浦承皓1王卫东2杨雪1
1.环境保护部核与辐射安全中心,北京 1000822.深圳中广核工程设计有限公司,广东 深圳 518172
Author(s):
LI Maolin1PU Chenghao1WANG Weidong2YANG Xue1
1.Nuclear and Radiation Safety Center,MEP,Beijing 100082,China2.China Nuclear Power Design Co.,Ltd.(Shenzhen), Shenzhen 518172,China
关键词:
奥氏体不锈钢无缝钢管硫酸-硫酸铜法晶间腐蚀
Keywords:
austenitic stainless steel seamless steel pipe copper sulfatesulfuric acid test intergranular corrosion
DOI:
10.7502/j.issn.1674-3962.2017.11.08
文献标志码:
A
摘要:
针对奥氏体不锈钢无缝钢管通过硫酸-硫酸铜法进行晶间腐蚀试验时,ASTM A262、NB/T 20004和GB/T 4334三个标准中对实验要求的差异进行探讨,主要从试样制备、敏化热处理制度、腐蚀试验和评定试验4个方面进行了分析对比,结果显示这三个标准之间存在着明显的差异,表明三个标准下硫酸-硫酸铜法晶间腐蚀试验之间没有必然的替代性,因此在一定程度上说明:不同材料体系中的奥氏体不锈钢无缝钢管,在进行晶间腐蚀试验时应按照相应的标准规定进行。
Abstract:
In this paper, the differences of intergranular corrosion test requirements using copper sulfatesulfuric acid test method in ASTM A262, NB/T 20004 and GB/T 4334 three standards were analyzed, and the conclusions were got through comparing from four aspects including specimen preparation, sensitization heat treatment, corrosion test and evaluation, it was concluded that the three standards are different, and there are no substitution among these standards. So to a certain extent, for austenitic seamless stainless steel pipe in different material systems, the intergranular corrosion test should be performed in accordance with the corresponding standard stipulated in the relative material procurement specifications.